Test Date: 2015-07-10 14:30
Analysis date: 2016-05-25 21:41
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
53.75 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.78 |
|
Rate |
Rate |
307.90 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
111.56 ± 0.08 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.37 |
|
Rate |
Rate |
468.90 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
142.36 ± 0.11 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
5.5 |
|
Rate |
Rate |
251.30 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
162.17 ± 0.13 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.56 |
|
Rate |
Rate |
160.70 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
42.414 ± 0.069 |
nElectrons/VCal |
Offset |
Offset |
121.225 ± 7.372 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
307.90 |
kHz/cm² |
NTrigs |
N Trig |
5918723 |
Trigger |
NHits |
N Hits |
28433 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
468.90 |
kHz/cm² |
NTrigs |
N Trig |
5919185 |
Trigger |
NHits |
N Hits |
43301 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
251.30 |
kHz/cm² |
NTrigs |
N Trig |
5919263 |
Trigger |
NHits |
N Hits |
23203 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
160.70 |
kHz/cm² |
NTrigs |
N Trig |
5918883 |
Trigger |
NHits |
N Hits |
14834 |
Hits |