Test Date: 2015-09-11 16:58
Analysis date: 2016-05-26 02:11
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
50.17 ± 0.09 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.34 |
|
Rate |
Rate |
242.90 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
101.5 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.54 |
|
Rate |
Rate |
423.20 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
128.08 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.89 |
|
Rate |
Rate |
230.00 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
145.78 ± 0.13 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
4.9 |
|
Rate |
Rate |
144.20 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
48.9 ± 0.147 |
nElectrons/VCal |
Offset |
Offset |
-107.753 ± 17.298 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
242.90 |
kHz/cm² |
NTrigs |
N Trig |
5916186 |
Trigger |
NHits |
N Hits |
22418 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
423.20 |
kHz/cm² |
NTrigs |
N Trig |
5916544 |
Trigger |
NHits |
N Hits |
39064 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
230.00 |
kHz/cm² |
NTrigs |
N Trig |
5916410 |
Trigger |
NHits |
N Hits |
21225 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
144.20 |
kHz/cm² |
NTrigs |
N Trig |
5916316 |
Trigger |
NHits |
N Hits |
13311 |
Hits |
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master