Test Date: 2016-01-18 14:11
Analysis date: 2016-05-26 08:38
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
50.55 ± 0.08 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.39 |
|
Rate |
Rate |
292.30 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
102.12 ± 0.07 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.48 |
|
Rate |
Rate |
446.00 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
129.85 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
3.68 |
|
Rate |
Rate |
233.40 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
147.44 ± 0.13 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
3.6 |
|
Rate |
Rate |
147.00 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
47.545 ± 0.061 |
nElectrons/VCal |
Offset |
Offset |
-3.308 ± 6.309 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
292.30 |
kHz/cm² |
NTrigs |
N Trig |
5915584 |
Trigger |
NHits |
N Hits |
26970 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
446.00 |
kHz/cm² |
NTrigs |
N Trig |
5915334 |
Trigger |
NHits |
N Hits |
41157 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
233.40 |
kHz/cm² |
NTrigs |
N Trig |
5915421 |
Trigger |
NHits |
N Hits |
21539 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
147.00 |
kHz/cm² |
NTrigs |
N Trig |
5915611 |
Trigger |
NHits |
N Hits |
13562 |
Hits |
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master