Test Date: 2016-04-14 11:21
Analysis date: 2016-05-26 14:41
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center |
Center of Peak |
52.28 ± 0.1 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.4 |
|
Rate |
Rate |
318.00 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center |
Center of Peak |
102.04 ± 0.08 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
1.63 |
|
Rate |
Rate |
467.40 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center |
Center of Peak |
129.14 ± 0.11 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.44 |
|
Rate |
Rate |
246.30 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center |
Center of Peak |
146.07 ± 0.14 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
2.57 |
|
Rate |
Rate |
155.80 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope |
Slope |
49.095 ± 0.077 |
nElectrons/VCal |
Offset |
Offset |
-163.454 ± 8.148 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate |
Rate |
318.00 |
kHz/cm² |
NTrigs |
N Trig |
5912310 |
Trigger |
NHits |
N Hits |
29330 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate |
Rate |
467.40 |
kHz/cm² |
NTrigs |
N Trig |
5914058 |
Trigger |
NHits |
N Hits |
43121 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate |
Rate |
246.30 |
kHz/cm² |
NTrigs |
N Trig |
5913810 |
Trigger |
NHits |
N Hits |
22727 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate |
Rate |
155.80 |
kHz/cm² |
NTrigs |
N Trig |
5913877 |
Trigger |
NHits |
N Hits |
14371 |
Hits |
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master