Test Date: 2016-04-25 09:19
Analysis date: 2016-05-26 15:48
Chip 8
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 55.52 ± 0.19 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 2.22
Rate Rate 306.60 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 107.71 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 2.61
Rate Rate 465.20 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 135.11 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.41
Rate Rate 248.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 153.97 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 6.35
Rate Rate 161.30 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 47.216 ± 0.133 nElectrons/VCal
Offset Offset -226.931 ± 14.905 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 306.60 kHz/cm²
NTrigs N Trig 5917012 Trigger
NHits N Hits 28301 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 465.20 kHz/cm²
NTrigs N Trig 5916857 Trigger
NHits N Hits 42938 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 248.80 kHz/cm²
NTrigs N Trig 5916672 Trigger
NHits N Hits 22967 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 161.30 kHz/cm²
NTrigs N Trig 5916764 Trigger
NHits N Hits 14888 Hits
MoReWeb-v1.0.0-5-g82d9ff6 on branch psi46master