Test Date: 2016-08-22 17:23
Analysis date: 2016-08-29 21:02
XrayQualification M2293
Comment |
Comment |
comments.txt:
Read-out errors in Channel 1 for the two highest rates "200" and "250". Max real rate tested for C0/C15 is around 110 MHz/cm2.
|
|
Module ID
|
Test Date
|
Analysis
|
Test Type
|
Grade
|
Pixel Defects
|
ROCs < 1%
|
ROCs > 1%
|
ROCs > 4%
|
Noise
|
Trimming
|
PHCalibration
|
I(150V)
|
I_rec(150V)
|
IV Slope
|
Temperature
|
initial Current
|
Comments
|
M2293
|
2016-08-22 17:23
|
|
XRayHRQualification
|
C
|
5
|
16
|
0
|
0
|
3
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
Grade manually changed from A to C
|
M2293
|
2016-08-22 17:23
|
|
XrayCalibration_Spectrum
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
M2293 ModuleQualification_SumOfCurrents
M2293 XRayHRQualification
Comment |
Comment |
comments.txt:
Read-out errors in Channel 1 for the two highest rates "200" and "250". Max real rate tested for C0/C15 is around 110 MHz/cm2.
|
|
Overview
X-ray Calibration - Spectrum
Slope |
avrg Slope |
46.4883125 |
|
Overview
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master