Test Date: 2016-09-27 09:25
Analysis date: 2016-09-27 11:29
XrayQualification M2337
Comment |
Comment |
comment.txt:
Not tested because Leakage current >100uA!
|
|
Module ID
|
Test Date
|
Analysis
|
Test Type
|
Grade
|
Pixel Defects
|
ROCs < 1%
|
ROCs > 1%
|
ROCs > 4%
|
Noise
|
Trimming
|
PHCalibration
|
I(150V)
|
I_rec(150V)
|
IV Slope
|
Temperature
|
initial Current
|
Comments
|
M2337
|
2016-09-27 09:25
|
2016-09-27 11:29
|
LeakageCurrentPON & LeakageCurrentPON
|
C
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
17.0 / 17.0
|
0.0001 / 0.0001
|
None
|
M2337
|
2016-09-27 09:25
|
|
XRayHRQualification
|
C
|
-1
|
16
|
0
|
0
|
0
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
Manually graded C (already C before)
|
M2337
|
2016-09-27 09:25
|
|
XrayCalibration_Spectrum
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
None
|
M2337 ModuleQualification_SumOfCurrents
M2337 XRayHRQualification
Comment |
Comment |
comment.txt:
Not tested because Leakage current >100uA!
|
|
Overview
X-ray Calibration - Spectrum
Overview
MoReWeb-v1.0.2-10-gbc52a17 on branch psi46master