Test Date: 2015-06-04 14:06
Chip 11
X-ray Calibration - Target Zn Method Spectrum Chip C11
Center |
Center of Peak |
49.28 ± 0.18 |
Vcal |
TargetEnergy |
Energy of target Zn |
8638.91 |
eV |
TargetNElectrons |
Energy of target Zn |
2399.7 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
124.82 |
|
Rate |
Rate |
796.90 |
kHz/cm² |
X-ray Calibration - Target Mo Method Spectrum Chip C11
Center |
Center of Peak |
102.11 ± 0.09 |
Vcal |
TargetEnergy |
Energy of target Mo |
17479.37 |
eV |
TargetNElectrons |
Energy of target Mo |
4855.38 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
136.37 |
|
Rate |
Rate |
982.80 |
kHz/cm² |
X-ray Calibration - Target Ag Method Spectrum Chip C11
Center |
Center of Peak |
131.06 ± 0.14 |
Vcal |
TargetEnergy |
Energy of target Ag |
22162.92 |
eV |
TargetNElectrons |
Energy of target Ag |
6156.37 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
144.45 |
|
Rate |
Rate |
737.00 |
kHz/cm² |
X-ray Calibration - Target Sn Method Spectrum Chip C11
Center |
Center of Peak |
149.24 ± 0.16 |
Vcal |
TargetEnergy |
Energy of target Sn |
25271.36 |
eV |
TargetNElectrons |
Energy of target Sn |
7019.82 |
nElectrons |
Chi2PerNDF |
Chi^2 per NDF |
144.78 |
|
Rate |
Rate |
658.30 |
kHz/cm² |
X-ray Calibration - Vcal Calibration Method Spectrum Chip C11
Slope |
Slope |
46.038 ± 0.102 |
nElectrons/VCal |
Offset |
Offset |
143.932 ± 11.491 |
nElectrons |
X-ray Hit Map - Target Zn Method Spectrum Chip C11
Rate |
Rate |
796.90 |
kHz/cm² |
NTrigs |
N Trig |
5913615 |
Trigger |
NHits |
N Hits |
73512 |
Hits |
X-ray Hit Map - Target Mo Method Spectrum Chip C11
Rate |
Rate |
982.80 |
kHz/cm² |
NTrigs |
N Trig |
5913760 |
Trigger |
NHits |
N Hits |
90672 |
Hits |
X-ray Hit Map - Target Ag Method Spectrum Chip C11
Rate |
Rate |
737.00 |
kHz/cm² |
NTrigs |
N Trig |
5913380 |
Trigger |
NHits |
N Hits |
67990 |
Hits |
X-ray Hit Map - Target Sn Method Spectrum Chip C11
Rate |
Rate |
658.30 |
kHz/cm² |
NTrigs |
N Trig |
5913488 |
Trigger |
NHits |
N Hits |
60731 |
Hits |