Test Date: 2015-06-04 14:06
Chip 2
X-ray Calibration - Target Zn Method Spectrum Chip C2
Center Center of Peak 49.62 ± 0.13 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 3.66
Rate Rate 179.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C2
Center Center of Peak 104.55 ± 0.1 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.16
Rate Rate 324.60 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C2
Center Center of Peak 133.64 ± 0.13 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.45
Rate Rate 181.60 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C2
Center Center of Peak 152.01 ± 0.16 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.0
Rate Rate 119.00 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C2
Slope Slope 44.711 ± 0.096 nElectrons/VCal
Offset Offset 181.062 ± 9.821 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C2
Rate Rate 179.70 kHz/cm²
NTrigs N Trig 5913615 Trigger
NHits N Hits 16575 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C2
Rate Rate 324.60 kHz/cm²
NTrigs N Trig 5913760 Trigger
NHits N Hits 29946 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C2
Rate Rate 181.60 kHz/cm²
NTrigs N Trig 5913380 Trigger
NHits N Hits 16751 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C2
Rate Rate 119.00 kHz/cm²
NTrigs N Trig 5913488 Trigger
NHits N Hits 10981 Hits