Test Date: 2015-05-26 14:05
Chip 9
X-ray Calibration - Target Zn Method Spectrum Chip C9
Center Center of Peak 46.67 ± 0.08 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 16.96
Rate Rate 373.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C9
Center Center of Peak 99.49 ± 0.06 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 7.27
Rate Rate 550.70 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C9
Center Center of Peak 127.23 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 6.0
Rate Rate 292.00 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C9
Center Center of Peak 146.1 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 5.94
Rate Rate 182.90 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C9
Slope Slope 46.534 ± 0.061 nElectrons/VCal
Offset Offset 227.367 ± 5.983 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C9
Rate Rate 373.10 kHz/cm²
NTrigs N Trig 5911837 Trigger
NHits N Hits 34405 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C9
Rate Rate 550.70 kHz/cm²
NTrigs N Trig 5911915 Trigger
NHits N Hits 50788 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C9
Rate Rate 292.00 kHz/cm²
NTrigs N Trig 5911947 Trigger
NHits N Hits 26928 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C9
Rate Rate 182.90 kHz/cm²
NTrigs N Trig 5911790 Trigger
NHits N Hits 16870 Hits