Test Date: 2015-04-08 11:04
Chip 3
X-ray Calibration - Target Cu Method Spectrum Chip C3
Center Center of Peak 46.6 ± 0.16 Vcal
TargetEnergy Energy of target Cu 8047.82 eV
TargetNElectrons Energy of target Cu 2235.51 nElectrons
Chi2PerNDF Chi^2 per NDF 20.57
Rate Rate 293.40 kHz/cm²
X-ray Calibration - Target Zn Method Spectrum Chip C3
Center Center of Peak 49.25 ± 0.15 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 20.54
Rate Rate 330.60 kHz/cm²
X-ray Calibration - Target Br Method Spectrum Chip C3
Center Center of Peak 64.44 ± 0.12 Vcal
TargetEnergy Energy of target Br 11924.36 eV
TargetNElectrons Energy of target Br 3312.32 nElectrons
Chi2PerNDF Chi^2 per NDF 14.33
Rate Rate 531.40 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C3
Center Center of Peak 95.12 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 8.28
Rate Rate 522.80 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C3
Center Center of Peak 120.01 ± 0.14 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 4.61
Rate Rate 277.50 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C3
Center Center of Peak 136.06 ± 0.17 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.34
Rate Rate 177.50 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C3
Slope Slope 52.705 ± 0.225 nElectrons/VCal
Offset Offset -159.428 ± 24.517 nElectrons
X-ray Hit Map - Target Cu Method Spectrum Chip C3
Rate Rate 293.40 kHz/cm²
NTrigs N Trig 2956043 Trigger
NHits N Hits 13528 Hits
X-ray Hit Map - Target Zn Method Spectrum Chip C3
Rate Rate 330.60 kHz/cm²
NTrigs N Trig 2956195 Trigger
NHits N Hits 15248 Hits
X-ray Hit Map - Target Br Method Spectrum Chip C3
Rate Rate 531.40 kHz/cm²
NTrigs N Trig 2956196 Trigger
NHits N Hits 24505 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C3
Rate Rate 522.80 kHz/cm²
NTrigs N Trig 2956455 Trigger
NHits N Hits 24111 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C3
Rate Rate 277.50 kHz/cm²
NTrigs N Trig 2956176 Trigger
NHits N Hits 12796 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C3
Rate Rate 177.50 kHz/cm²
NTrigs N Trig 2956336 Trigger
NHits N Hits 8184 Hits