Test Date: 2015-04-08 11:04
Chip 5
X-ray Calibration - Target Cu Method Spectrum Chip C5
Center Center of Peak 46.15 ± 0.12 Vcal
TargetEnergy Energy of target Cu 8047.82 eV
TargetNElectrons Energy of target Cu 2235.51 nElectrons
Chi2PerNDF Chi^2 per NDF 18.91
Rate Rate 343.60 kHz/cm²
X-ray Calibration - Target Zn Method Spectrum Chip C5
Center Center of Peak 49.26 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 19.73
Rate Rate 393.50 kHz/cm²
X-ray Calibration - Target Br Method Spectrum Chip C5
Center Center of Peak 64.47 ± 0.13 Vcal
TargetEnergy Energy of target Br 11924.36 eV
TargetNElectrons Energy of target Br 3312.32 nElectrons
Chi2PerNDF Chi^2 per NDF 11.81
Rate Rate 593.40 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C5
Center Center of Peak 96.79 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 7.58
Rate Rate 563.00 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C5
Center Center of Peak 123.42 ± 0.14 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.23
Rate Rate 290.50 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C5
Center Center of Peak 141.16 ± 0.17 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.74
Rate Rate 182.00 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C5
Slope Slope 48.801 ± 0.193 nElectrons/VCal
Offset Offset 132.101 ± 21.566 nElectrons
X-ray Hit Map - Target Cu Method Spectrum Chip C5
Rate Rate 343.60 kHz/cm²
NTrigs N Trig 2956043 Trigger
NHits N Hits 15845 Hits
X-ray Hit Map - Target Zn Method Spectrum Chip C5
Rate Rate 393.50 kHz/cm²
NTrigs N Trig 2956195 Trigger
NHits N Hits 18146 Hits
X-ray Hit Map - Target Br Method Spectrum Chip C5
Rate Rate 593.40 kHz/cm²
NTrigs N Trig 2956196 Trigger
NHits N Hits 27366 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C5
Rate Rate 563.00 kHz/cm²
NTrigs N Trig 2956455 Trigger
NHits N Hits 25964 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C5
Rate Rate 290.50 kHz/cm²
NTrigs N Trig 2956176 Trigger
NHits N Hits 13399 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C5
Rate Rate 182.00 kHz/cm²
NTrigs N Trig 2956336 Trigger
NHits N Hits 8393 Hits