Test Date: 2015-04-08 11:04
Chip 8
X-ray Calibration - Target Cu Method Spectrum Chip C8
Center Center of Peak 47.88 ± 0.11 Vcal
TargetEnergy Energy of target Cu 8047.82 eV
TargetNElectrons Energy of target Cu 2235.51 nElectrons
Chi2PerNDF Chi^2 per NDF 7.95
Rate Rate 319.30 kHz/cm²
X-ray Calibration - Target Zn Method Spectrum Chip C8
Center Center of Peak 51.15 ± 0.11 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 7.49
Rate Rate 337.20 kHz/cm²
X-ray Calibration - Target Br Method Spectrum Chip C8
Center Center of Peak 67.31 ± 0.13 Vcal
TargetEnergy Energy of target Br 11924.36 eV
TargetNElectrons Energy of target Br 3312.32 nElectrons
Chi2PerNDF Chi^2 per NDF 5.44
Rate Rate 541.70 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C8
Center Center of Peak 101.63 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 3.6
Rate Rate 530.00 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C8
Center Center of Peak 129.81 ± 0.14 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 3.64
Rate Rate 287.00 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C8
Center Center of Peak 148.54 ± 0.16 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 3.24
Rate Rate 183.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C8
Slope Slope 46.147 ± 0.167 nElectrons/VCal
Offset Offset 165.564 ± 19.778 nElectrons
X-ray Hit Map - Target Cu Method Spectrum Chip C8
Rate Rate 319.30 kHz/cm²
NTrigs N Trig 2956043 Trigger
NHits N Hits 14722 Hits
X-ray Hit Map - Target Zn Method Spectrum Chip C8
Rate Rate 337.20 kHz/cm²
NTrigs N Trig 2956195 Trigger
NHits N Hits 15549 Hits
X-ray Hit Map - Target Br Method Spectrum Chip C8
Rate Rate 541.70 kHz/cm²
NTrigs N Trig 2956196 Trigger
NHits N Hits 24980 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C8
Rate Rate 530.00 kHz/cm²
NTrigs N Trig 2956455 Trigger
NHits N Hits 24446 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C8
Rate Rate 287.00 kHz/cm²
NTrigs N Trig 2956176 Trigger
NHits N Hits 13234 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C8
Rate Rate 183.70 kHz/cm²
NTrigs N Trig 2956336 Trigger
NHits N Hits 8473 Hits