Test Date: 2015-05-21 18:05
Chip 2
X-ray Calibration - Target Zn Method Spectrum Chip C2
Center Center of Peak 55.02 ± 0.1 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 7.61
Rate Rate 191.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C2
Center Center of Peak 112.32 ± 0.09 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 5.83
Rate Rate 342.30 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C2
Center Center of Peak 144.07 ± 0.11 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 5.9
Rate Rate 200.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C2
Center Center of Peak 163.71 ± 0.15 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 4.74
Rate Rate 130.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C2
Slope Slope 42.37 ± 0.058 nElectrons/VCal
Offset Offset 76.336 ± 6.805 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C2
Rate Rate 191.10 kHz/cm²
NTrigs N Trig 5910555 Trigger
NHits N Hits 17621 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C2
Rate Rate 342.30 kHz/cm²
NTrigs N Trig 5910983 Trigger
NHits N Hits 31565 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C2
Rate Rate 200.80 kHz/cm²
NTrigs N Trig 5941040 Trigger
NHits N Hits 18606 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C2
Rate Rate 130.70 kHz/cm²
NTrigs N Trig 5909762 Trigger
NHits N Hits 12051 Hits