Test Date: 2015-05-21 18:05
Chip 5
X-ray Calibration - Target Zn Method Spectrum Chip C5
Center Center of Peak 53.97 ± 0.07 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 26.32
Rate Rate 392.10 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C5
Center Center of Peak 108.68 ± 0.06 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 11.44
Rate Rate 551.40 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C5
Center Center of Peak 138.44 ± 0.09 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 8.59
Rate Rate 291.80 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C5
Center Center of Peak 156.93 ± 0.1 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 7.57
Rate Rate 185.40 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C5
Slope Slope 44.728 ± 0.046 nElectrons/VCal
Offset Offset -12.509 ± 5.114 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C5
Rate Rate 392.10 kHz/cm²
NTrigs N Trig 5910555 Trigger
NHits N Hits 36150 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C5
Rate Rate 551.40 kHz/cm²
NTrigs N Trig 5910983 Trigger
NHits N Hits 50841 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C5
Rate Rate 291.80 kHz/cm²
NTrigs N Trig 5941040 Trigger
NHits N Hits 27043 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C5
Rate Rate 185.40 kHz/cm²
NTrigs N Trig 5909762 Trigger
NHits N Hits 17092 Hits