Test Date: 2015-07-07 08:07
Chip 3
X-ray Calibration - Target Zn Method Spectrum Chip C3
Center Center of Peak 52.5 ± 0.13 Vcal
TargetEnergy Energy of target Zn 8638.91 eV
TargetNElectrons Energy of target Zn 2399.7 nElectrons
Chi2PerNDF Chi^2 per NDF 34.27
Rate Rate 292.30 kHz/cm²
X-ray Calibration - Target Mo Method Spectrum Chip C3
Center Center of Peak 111.01 ± 0.08 Vcal
TargetEnergy Energy of target Mo 17479.37 eV
TargetNElectrons Energy of target Mo 4855.38 nElectrons
Chi2PerNDF Chi^2 per NDF 35.72
Rate Rate 516.20 kHz/cm²
X-ray Calibration - Target Ag Method Spectrum Chip C3
Center Center of Peak 140.7 ± 0.12 Vcal
TargetEnergy Energy of target Ag 22162.92 eV
TargetNElectrons Energy of target Ag 6156.37 nElectrons
Chi2PerNDF Chi^2 per NDF 18.18
Rate Rate 261.60 kHz/cm²
X-ray Calibration - Target Sn Method Spectrum Chip C3
Center Center of Peak 161.02 ± 0.14 Vcal
TargetEnergy Energy of target Sn 25271.36 eV
TargetNElectrons Energy of target Sn 7019.82 nElectrons
Chi2PerNDF Chi^2 per NDF 16.68
Rate Rate 170.70 kHz/cm²
X-ray Calibration - Vcal Calibration Method Spectrum Chip C3
Slope Slope 43.412 ± 0.13 nElectrons/VCal
Offset Offset 38.064 ± 16.793 nElectrons
X-ray Hit Map - Target Zn Method Spectrum Chip C3
Rate Rate 292.30 kHz/cm²
NTrigs N Trig 5919755 Trigger
NHits N Hits 26990 Hits
X-ray Hit Map - Target Mo Method Spectrum Chip C3
Rate Rate 516.20 kHz/cm²
NTrigs N Trig 5919616 Trigger
NHits N Hits 47672 Hits
X-ray Hit Map - Target Ag Method Spectrum Chip C3
Rate Rate 261.60 kHz/cm²
NTrigs N Trig 5915229 Trigger
NHits N Hits 24139 Hits
X-ray Hit Map - Target Sn Method Spectrum Chip C3
Rate Rate 170.70 kHz/cm²
NTrigs N Trig 5919108 Trigger
NHits N Hits 15763 Hits