Test Date: 2016-12-05 11:58
Analysis date: 2016-12-05 12:01
OnShellQuickTest M1053
Comment |
Comment |
comments.txt:
had read out errors which lead to missing data in 1 channel -> cable replaced -> OK
|
|
Module ID
|
Test Date
|
Analysis
|
Test Type
|
Grade
|
Pixel Defects
|
ROCs < 1%
|
ROCs > 1%
|
ROCs > 4%
|
Noise
|
Trimming
|
PHCalibration
|
I(150V)
|
I_rec(150V)
|
IV Slope
|
Temperature
|
initial Current
|
Comments
|
M1053
|
2016-12-05 11:58
|
|
OnShellQuickTest_p17_1
|
B
|
143
|
15
|
1
|
0
|
None
|
None
|
None
|
1.64
|
0.34
|
-1.0
|
-1
|
0.49
|
had read out errors which lead to missing data in 1 channel -> cable replaced -> OK
|
M1053 ModuleQualification_Temperature
M1053 ModuleQualification_Humidity
M1053 ModuleQualification_SumOfCurrents
M1053 ModuleOnShellQuickTest_p17_1
Overview
v1.1.1-16-g393687a
on branch psi46master